thumb|Small Form-factor Pluggable connected to a pair of [[fiber-optic cables]]
Small Form-factor Pluggable (SFP) is a compact, hot-pluggable network interface module format used for both telecommunication and data communications applications. An SFP interface on networking hardware is a modular slot for a media-specific transceiver, such as for a fiber-optic cable or a copper cable. In 2006, SFP+ specification brought speeds up to and the later SFP28 iteration, introduced in 2014, is designed for speeds of . There are inexpensive adapters allowing SFP transceivers to be placed in a QSFP port.
Both a SFP-DD,
An even larger sibling, the Octal Small Format Pluggable (OSFP), had products released in 2022 capable of links between network equipment. It is a slightly larger version than the QSFP form factor allowing for larger power outputs. The OSFP standard was initially announced in 2016 Its proponents say a low-cost adapter will allow for backwards compatibility with QSFP modules.
SFP types
SFP transceivers are available with a variety of transmitter and receiver specifications, allowing users to select the appropriate transceiver for each link to provide the required optical or electrical reach over the available media type (e.g. twisted pair or twinaxial copper cables, multi-mode or single-mode fiber cables). Transceivers are also designated by their transmission speed. SFP modules are commonly available in several different categories.
{| class="wikitable" style="text-align:center;"
|+ Comparison of SFP types
|-
! Name
! Nominal <br/>speed
! Lanes
! Standard
! Introduced
! Backward-compatible
! PHY interface
! Connector
|-
| align="left" | SFP
|
| 1
| SFF INF-8074i
| 2001-05-01
|
| MII
| LC, RJ45
|-
| align="left" | SFP
|
| 1
| SFF INF-8074i
| 2001-05-01
| SFP*
| SGMII
| LC, RJ45
|-
| align="left" | cSFP
|
| 2
|
|
|
|
| LC
|-
| align="left" |SFP+
|
| 1
| SFF SFF-8431 4.1
| 2009-07-06
| SFP
| XGMII
| LC, RJ45
|-
| align="left" | SFP28
|
| 1
| SFF SFF-8402
| 2014-09-13
| SFP, SFP+
|
| LC
|-
| align="left" | SFP56
|
| 1
|
|
| SFP, SFP+, SFP28
|
| LC
|-
| align="left" | SFP-DD
|
| 2
| rowspan="3" | SFP-DD MSA QSFP56
|
| LC,
|}
Note that the QSFP/QSFP+/QSFP28/QSFP56 are designed to be electrically backward compatible with SFP/SFP+/SFP28 or SFP56 respectively. Using a simple adapter or a special direct attached cable it is possible to connect those interfaces together using just one lane instead of four provided by the QSFP/QSFP+/QSFP28/QSFP56 form factor. The same applies to the QSFP-DD form factor with 8 lanes which can work downgraded to 4/2/1 lanes.
SFP
<!--Information below would probably be better presented as a table-->
<!--https://members.snia.org/document/dl/26184-->
- Multi-mode fiber, LC connector, with or color coding
- SX850 nm, for a maximum of 550 m
- Multi-mode fiber, LC connector, with color coding
- FX 1300 nm, for a distance up to 5 km.
- LFX (name dependent on manufacturer)1310 nm, for a distance up to 5 km.
- Single-mode fiber, LC connector, with color coding
- LX1310 nm, for distances up to 10 km
- EX1310 nm, for distances up to 40 km
- Single-mode fiber, LC connector, with color coding
- ZX1550 nm, for distances up to 80 km, (depending on fiber path loss)
- EZX1550 nm, for distances up to 160 km (depending on fiber path loss)
- Single-mode fiber, LC connector, Bi-Directional, with and color coding
- BX (officially BX10)1550 nm/1310 nm, Single Fiber Bi-Directional 100 Mbit SFP Transceivers, paired as BX-U () and BX-D () for uplink and downlink respectively, also for distances up to 10 km. Variations of bidirectional SFPs are also manufactured which higher transmit power versions with link length capabilities up to 40 km.
- Copper twisted-pair cabling, 8P8C (RJ-45) connector
- 100BASE-TX for distances up to 100m.
SFP
<!--Information below would probably be better presented as a table-->
- 1 to 1. multi-mode fiber, LC connector, with black or beige extraction lever
- 1 to 1. multi-mode fiber, LC connector, extraction lever colors not standardized
- SX+/MX/LSX/LX (name dependent on manufacturer)1310 nm, for a distance up to 2 km. Not compatible with SX or 100BASE-FX. Based on LX but engineered to work with a multi-mode fiber using a standard multi-mode patch cable rather than a mode-conditioning cable commonly used to adapt LX to multi-mode.
- 1 to 2. single-mode fiber, LC connector, with blue extraction lever Variations of bidirectional SFPs are also manufactured which use 1550 nm in one direction, and higher transmit power versions with link length capabilities up to 80 km.
- 1550 nm 40 km (XD), 80 km (ZX), 120 km (EX or EZX)
- SFSWsingle-fiber single-wavelength transceivers, for bi-directional traffic on a single fiber. Coupled with CWDM, these double the traffic density of fiber links.
- Coarse wavelength-division multiplexing (CWDM) and dense wavelength-division multiplexing (DWDM) transceivers at various wavelengths achieve various maximum distances. CWDM and DWDM transceivers usually support link distances of 40, 80 and 120 km.
- for copper twisted-pair cabling, 8P8C (RJ-45) connector
- 1000BASE-Tthese modules incorporate significant interface circuitry for Physical Coding Sublayer recoding and can be used only for gigabit Ethernet because of the specific line code. They are not compatible with (or rather: do not have equivalents for) Fibre Channel or SONET. Unlike most non-SFP, copper 1000BASE-T ports integrated into most routers and switches, 1000BASE-T SFPs usually cannot operate at 100BASE-TX speeds.
- copper and opticalsome vendors have shipped limited SFPs for fiber-to-the-home applications and drop-in replacement of legacy 100BASE-FX circuits. These are relatively uncommon and can be easily confused with SFPs.
- Although it is not mentioned in any official specification document the maximum data rate of the original SFP standard is . This was eventually used by both 4GFC Fibre Channel and the DDR Infiniband especially in its four-lane QSFP form.
- In recent years, SFP transceivers have been created that will allow 2. and Ethernet speeds with SFPs with 2.5GBASE-T and 5GBASE-T.
SFP+<!--Enhanced small form-factor pluggable transceiver redirects here-->
thumb|350px|right|A [[10 Gigabit Ethernet XFP transceiver, top, and a SFP+ transceiver, bottom]]
The SFP+ (enhanced small form-factor pluggable) is an enhanced version of the SFP that supports data rates up to 16 Gbit/s. The SFP+ specification was first published on May 9, 2006, and version 4.1 was published on July 6, 2009. SFP+ supports Fibre Channel, 10 Gigabit Ethernet and Optical Transport Network standard OTU2. It is a popular industry format supported by many network component vendors. Although the SFP+ standard does not include mention of Fibre Channel, it can be used at this speed. Besides the data rate, the major difference between 8 and Fibre Channel is the encoding method. The 64b/66b encoding used for is a more efficient encoding mechanism than 8b/10b used for , and allows for the data rate to double without doubling the line rate. 16GFC doesn't really use signaling anywhere. It uses a 14. line rate to achieve twice the throughput of 8GFC.
SFP+ also introduces direct attach for connecting two SFP+ ports without dedicated transceivers. Direct attach cables (DAC) exist in passive (up to 7 m), active (up to 15 m), and active optical (AOC, up to 100 m) variants.
SFP+ modules are exactly the same dimensions as regular SFPs, allowing the equipment manufacturer to re-use existing physical designs for 24 and 48-port switches and modular line cards. In comparison to earlier XENPAK or XFP modules, SFP+ modules leave more circuitry to be implemented on the host board instead of inside the module. Through the use of an active electronic adapter, SFP+ modules may be used in older equipment with XENPAK ports and X2 ports.
SFP+ modules can be described as limiting or linear types; this describes the functionality of the inbuilt electronics. Limiting SFP+ modules include a signal amplifier to re-shape the (degraded) received signal whereas linear ones do not. Linear modules are mainly used with the low bandwidth standards such as 10GBASE-LRM; otherwise, limiting modules are preferred.
SFP28
SFP28 is a interface which evolved from the 100 Gigabit Ethernet interface which is typically implemented with 4 by data lanes. Identical in mechanical dimensions to SFP and SFP+, SFP28 implements one lane accommodating of data with encoding overhead.
SFP28 modules exist supporting single- or multi-mode fiber connections, active optical cable and direct attach copper.
cSFP
The compact small form-factor pluggable (cSFP) is a version of SFP with the same mechanical form factor allowing two independent bidirectional channels per port. It is used primarily to increase port density and decrease fiber usage per port.
SFP-DD
The small form-factor pluggable double density (SFP-DD) multi-source agreement is a standard published in 2019 for doubling port density. According to the SFD-DD MSA website: "Network equipment based on the SFP-DD will support legacy SFP modules and cables, and new double density products."
SFP-DD uses two lanes to transmit.
Currently, the following speeds are defined:
- SFP112: using PAM4 on a single pair (not double density)
- SFP-DD: using PAM4 and using NRZ
- QSFP-DD: / (8 × and 8 × )
- QSFP-DD800 (formerly QSFP-DD112): (8 × )
QSFP
thumb|QSFP+ 40 Gb transceiver
alt=Disassembled QSFP transciever showing the optical fibre connection and electronics |thumb|40 Gbit QSFP+ transceiver showing the optical fibre connection
Quad Small Form-factor Pluggable (QSFP) transceivers are available with a variety of transmitter and receiver types, allowing users to select the appropriate transceiver for each link to provide the required optical reach over multi-mode or single-mode fiber.
; : The original QSFP document specified four channels carrying Gigabit Ethernet, 4GFC (FiberChannel), or DDR InfiniBand.
; (QSFP+): QSFP+ is an evolution of QSFP to support four channels carrying 10 Gigabit Ethernet, 10GFC FiberChannel, or QDR InfiniBand. The 4 channels can also be combined into a single 40 Gigabit Ethernet link.
; (QSFP14): The QSFP14 standard is designed to carry FDR InfiniBand, SAS-3 or 16G Fibre Channel.
; (QSFP28): The QSFP28 standard for sake of simplicity.
; (QSFP56): QSFP56 is designed to carry 200 Gigabit Ethernet, HDR InfiniBand, or 64G Fibre Channel. The biggest enhancement is that QSFP56 uses four-level pulse-amplitude modulation (PAM-4) instead of non-return-to-zero (NRZ). It uses the same physical specifications as QSFP28 (SFF-8665), with electrical specifications from SFF-8024 and revision 2.10a of SFF-8636. Sometimes this transceiver type is referred to as 200G QSFP for sake of simplicity.
Switch and router manufacturers implementing QSFP+ ports in their products frequently allow for the use of a single QSFP+ port as four independent 10 Gigabit Ethernet connections, greatly increasing port density. For example, a typical 24-port QSFP+ 1U switch would be able to service 96x10GbE connections. There also exist fanout cables to adapt a single QSFP28 port to four independent 25 Gigabit Ethernet SFP28 ports (QSFP28-to-4×SFP28) as well as cables to adapt a single QSFP56 port to four independent 50 Gigabit Ethernet SFP56 ports (QSFP56-to-4×SFP56).
Applications
thumb|400px|Ethernet switch with two empty SFP slots (lower left)
SFP sockets are found in Ethernet switches, routers, firewalls and network interface cards. They are used in Fibre Channel host adapters and storage equipment. Because of their low cost, low profile, and ability to provide a connection to different types of optical fiber, SFP provides such equipment with enhanced flexibility.
SFP sockets and transceivers are also used for long-distance serial digital interface (SDI) transmission.
Standardization
The SFP transceiver is not standardized by any official standards body, but rather is specified by a multi-source agreement (MSA) among competing manufacturers. The SFP was designed after the GBIC interface, and allows greater port density (number of transceivers per given area) than the GBIC, which is why SFP is also known as mini-GBIC.
However, as a practical matter, some networking equipment manufacturers engage in vendor lock-in practices whereby they deliberately break compatibility with generic SFPs by adding a check in the device's firmware that will enable only the vendor's own modules. Third-party SFP manufacturers have introduced SFPs with EEPROMs which may be programmed to match any vendor ID.
Color coding of SFP
Color coding of SFP
<!------>
{| class="wikitable" style="text-align: center; "
|-
! Color
! Standard
! Media
! Wavelength
! Notes
|-
| style="background-color:Black" | <p style="color:White;">Black</p>
| INF-8074
| Multimode
| style="background-color:#C66995" | 850 nm
|
|-
| style="background-color:Beige" |
| INF-8074
| Multimode
| style="background-color:#C66995" | 850 nm
|
|-
| style="background-color:Black" | <p style="color:White;">Black</p>
| INF-8074
| Multimode
| style="background-color:#C66995" | 1300 nm
|
|-
| style="background-color:Blue" | <p style="color:White;">Blue</p>
| INF-8074
| Singlemode
| style="background-color:yellow" | 1310 nm
|
|-
| style="background-color:Red" |
|
| Singlemode
| style="background-color:yellow" | 1310 nm
| Used on 25GBASE-ER
|-
| style="background-color:Green" |
|
| Singlemode
| style="background-color:yellow" | 1550 nm
| Used on 100BASE-ZE
|-
| style="background-color:Red" |
|
| Singlemode
| style="background-color:yellow" | 1550 nm
| Used on 10GBASE-ER
|-
| style="background-color:White" |
|
| Singlemode
| style="background-color:yellow" | 1550 nm
| Used on 10GBASE-ZR
|}
Color coding of CWDM SFP
See also: coarse wavelength-division multiplexing
<!------>
{| class="wikitable" style="text-align: center; "
|-
! Color
! Standard
! Wavelength
! Notes
|-
| style="background-color:Grey" |
|
| 1270 nm
|
|-
| style="background-color:Grey" |
|
| 1290 nm
|
|-
| style="background-color:Grey" |
|
| 1310 nm
|
|-
| style="background-color:Violet" |
|
| 1330 nm
|
|-
| style="background-color:blue" |
|
| 1350 nm
|
|-
| style="background-color:Green" |
|
| 1370 nm
|
|-
| style="background-color:Yellow" |
|
| 1390 nm
|
|-
| style="background-color:Orange" |
|
| 1410 nm
|
|-
| style="background-color:Red" |
|
| 1430 nm
|
|-
| style="background-color:Brown" |
|
| 1450 nm
|
|-
| style="background-color:Grey" |
|
| 1470 nm
|
|-
| style="background-color:Violet" |
|
| 1490 nm
|
|-
| style="background-color:Blue" |
|
| 1510 nm
|
|-
| style="background-color:Green" |
|
| 1530 nm
|
|-
| style="background-color:Yellow" |
|
| 1550 nm
|
|-
| style="background-color:Orange" |
|
| 1570 nm
|
|-
| style="background-color:Red" |
|
| 1590 nm
|
|-
| style="background-color:Brown" |
|
| 1610 nm
|
|}
Color coding of BiDi SFP
<!------>
{| class="wikitable" style="text-align: center; "
|-
! Name
! Standard
! Side A Color TX
! Side A wavelength TX
! Side B Color TX
! Side B wavelength TX
! Notes
|-
| 1000BASE-BX
|
| style="background-color:Blue" |
| 1310 nm
| style="background-color:purple" |
| 1490 nm
|
|-
| 1000BASE-BX
|
| style="background-color:Blue" |
| 1310 nm
| style="background-color:yellow" |
| 1550 nm
|
|-
| 10GBASE-BX <br /> 25GBASE-BX
|
| style="background-color:Blue" |
| 1270 nm
| style="background-color:red" |
| 1330 nm
|
|-
| 10GBASE-BX
|
| style="background-color:White" |
| 1490 nm
| style="background-color:White" |
| 1550 nm
|
|}
Color coding of QSFP
<!------>
{| class="wikitable" style="text-align: center; "
|-
! Color
! Standard
! Wavelength
! Multiplexing
! Notes
|-
| style="background-color:Beige" |
| INF-8438
| style="background-color:#C66995" | 850 nm
| No
|
|-
| style="background-color:Blue" |
| INF-8438
| style="background-color:yellow" | 1310 nm
| No
|
|-
| style="background-color:White" |
| INF-8438
| style="background-color:yellow" | 1550 nm
| No
|
|}
Signals
thumb|right|Front view of SFP module with integrated [[LC connector indicating transmission direction of the two optical connectors]]
thumb|Disassembled OC-3 SFP. The top, metal canister is the transmitting laser diode, the bottom, plastic canister is the receiving photo diode.
When looking into the optical connectors, the one on the left is the transmitter and the one on the right is the receiver.
The SFP transceiver contains a printed circuit board with an edge connector with 20 pads that mate on the rear with the SFP electrical connector in the host system. The QSFP has 38 pads including 4 high-speed transmit data pairs and 4 high-speed receive data pairs.)
|-
| 5
| SCL
| 2-wire serial interface clock
|-
| 6
| Mod_ABS
| Module absent, connection to VeeT or VeeR in the module indicates module presence to host
|-
| 7
| RS0
| Rate select 0
|-
| 8
| Rx_LOS
| Receiver loss of signal indication
|-
| 9
| RS1
| Rate select 1
|-
| 10
| VeeR
| Receiver ground
|-
| 11
| VeeR
| Receiver ground
|-
| 12
| RD-
| Inverted received data
|-
| 13
| RD+
| Received data
|-
| 14
| VeeR
| Receiver ground
|-
| 15
| VccR
| Receiver power (3.3 V, max. 300 mA)
|-
| 16
| VccT
| Transmitter power (3.3 V, max. 300 mA)
|-
| 17
| VeeT
| Transmitter ground
|-
| 18
| TD+
| Transmit data
|-
| 19
| TD-
| Inverted transmit data
|-
| 20
| VeeT
| Transmitter ground
|-
|}
{|
|+QSFP electrical pin-out
|-
! mm !! in !! mm !! in !! mm !! in
|-
! Height
|
|
|
|-
! Width
|
|
|
|-
! Depth
|
|
|
|}
EEPROM information and Management Interface
The SFP MSA defines a 256-byte memory map into an EEPROM describing the transceiver's capabilities, standard interfaces, manufacturer, and other information, which is accessible over a serial I²C interface at the 8-bit address 0b1010000X (0xA0).
Later standards also specify (volatile) memory locations which offer the ability to observe and change the behavior of the transceiver.
{| class="wikitable"
|+ Management interface standards
|-
! Form factor !! Management interface standard
|-
| SFP+ || SFF-8472
|-
| QSFP+ || SFF-8636
|}
Digital diagnostics monitoring
Modern optical SFP transceivers support standard digital diagnostics monitoring (DDM) functions. This feature is also known as digital optical monitoring (DOM). This capability allows monitoring of the SFP operating parameters in real time. Parameters include optical output power, optical input power, temperature, laser bias current, and transceiver supply voltage. In network equipment, this information is typically made available via Simple Network Management Protocol (SNMP). A DDM interface allows end users to display diagnostics data and alarms for optical fiber transceivers and can be used to diagnose why a transceiver is not working.
See also
- Interconnect bottleneck
- Optical communication
- Parallel optical interface
- C form-factor pluggable
References
External links
- SNIA SFF Technology Affiliate Technical Work Group